1. The display screen of integrated stove does not light up
- Power cord falls off or leakage‑protection plug is damaged. Refer to the wiring diagram, inspect and repair or replace the parts accordingly.
- Power board or main control board is damaged. Inspect and judge, then repair or replace.
2. The fan of integrated stove fails to rotate
- Power cord falls off or leakage‑protection plug is damaged. Refer to the wiring diagram, inspect and repair or replace the parts accordingly.
- Power board or main control board is damaged. Inspect and judge, then repair or replace.
- Motor temperature rise exceeds 125 ℃. Normal operation may resume after cooling down. If the motor is burned out, it shall be replaced.
- Poor contact of control wire connector. Check the plug according to the circuit connection diagram to ensure reliable contact.
- Capacitor is damaged; replace the capacitor.
3. Difficult ignition of integrated stove
- The ignition knob is not turned by 90°, resulting in small gas outlet and insufficient gas supply for normal combustion. Turn the ignition knob to the correct position as required.
- Weak ignition spark: replace the battery.
- Blocked gas path. Check whether the gas passage between main gas pipe and branch gas pipe is unobstructed, and inspect if the nozzle is clogged.
- The ignition slot of burner cap is misaligned with ignition electrode. Rotate the aluminum burner cap for proper alignment.
- Ignition slot of burner cap is clogged; remove blockages from the slot.
- Excessive air trapped in gas pipe. Extend ignition duration until air inside the pipe is fully exhausted.
- Oxidized ignition electrode; clean it with dry cloth.
- Bent or flattened metal hose. Straighten the metal hose and check for gas leakage.
4. Frequent automatic flame‑out after ignition
- No flame covers thermocouple (ion‑sensing probe); adjust its position.
- Abnormal flame at thermocouple position; adjust air damper of inner burner ring.
- Damaged pulse igniter or solenoid valve; test and replace the faulty component.
5. Poor flame performance
- Blocked gas path. Check whether the gas passage between main gas pipe and branch gas pipe is unobstructed, and inspect if the nozzle is clogged.
- Poor‑quality gas or residual gas in LPG cylinder; replace the gas source.
- Wet burner assembly; let it air‑dry naturally to restore normal state.
- Clogged flame ports; clear obstructions in flame ports.
- Burner cap and aluminum cap are not seated properly. Fit the burner cap onto positioning pins.
- Improper air‑damper adjustment; tune air damper to obtain optimal flame condition.
6. Abnormal combustion noise
- Poor‑quality gas or residual gas in LPG cylinder; replace the gas source.
- Clogged flame ports; clear obstructions in flame ports.
- Burner cap and aluminum cap are not seated properly. Fit the burner cap onto positioning pins.
- Improper air‑damper adjustment; tune air damper to obtain optimal flame condition.
7. Disinfection cabinet of integrated stove does not work
- Power board or main control board is damaged. Inspect and judge, then repair or replace.
- Cabinet door is not fully closed or deformed. Close the door tightly or reshape the magnetic sealing gasket.
- Damaged door‑control switch; replace the switch.
8. Abnormal operation of induction cooker module
- Incompatible cookware. Use cookware complying with requirements specified in user manual.
- Uneven pot bottom; replace with cookware with flat bottom.
- Cookware is offset from center. Place cookware at the center of ceramic glass plate.
9. Poor fume‑extraction performance
- Abnormal three‑speed fan. Check fan operation and eliminate faults.
- Blocked exhaust duct. Keep duct unobstructed without squeezing or collapsing.
- Non‑return damper cannot open. Inspect opening status of non‑return damper, adjust or clean it.
- Inlet (mesh cover) and outlet of stove chamber are clogged; remove blockages.
- Excessively long duct with too many elbows. Shorten duct and reduce the number of elbows.
10. EO alarm code
- Power board or main control board is damaged. Inspect and judge, then repair or replace.
- Poor connection or crack on metal hose; reconnect firmly or replace the hose.
- Gas leakage from valve body; send to service center for repair or replace the valve.
- Odor exists in kitchen (e.g. paint odor). Remove odor or strengthen kitchen ventilation.